Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Arq. bras. endocrinol. metab ; 51(7): 1166-1168, out. 2007. ilus
Article in English | LILACS | ID: lil-470082

ABSTRACT

Parathyroid scintigraphies have been used to detect pathological parathyroid glands either before as well as after the parathyroid resection surgery in patients with hyperparathyroidism. One of the most utilized techniques to perform the studies is the double-phase images with Tc-99m sestamibi, which has been shown to be very accurate in the localization of enlarged parathyroid glands. Similar to Tc-99m sestamibi, Tc-99m tetrofosmin is a radiopharmaceutical initially developed to perform myocardial perfusion study that has been used to perform parathyroid scintigraphies. Although most of the papers suggest that the overall sensitivities of both radiopharmaceuticals are similar, there are some papers questioning the accuracy of Tc-99m tetrofosmin to detect abnormal parathyroid glands. In the present article, we report a case with discordant results by both methods.


A cintilografia das paratireóides tem sido utilizada para detectar glândulas paratireóides patológicas tanto antes quanto após (em caso de insucesso) a cirurgia de ressecção em pacientes com hiperparatireoidismo. Uma das técnicas mais utilizadas para realizar este exame é a de duas fases utilizando como radiofármaco o sestamibi-99mTc, a qual tem se mostrado acurada na localização de glândulas paratireóides aumentadas. Similarmente ao sestamibi-99mTc, o tetrofosmin-99mTc é um radiofármaco que foi inicialmente desenvolvido para a realização de cintilografia de perfusão do miocárdio e que tem sido utilizado para a realização de cintilografia das paratireóides. Apesar de muitos artigos sugerirem que as sensibilidades dos dois radiofármacos são idênticas, alguns poucos trabalhos questionam a acurácia do tetrofosmin-99mTc para a localização de glândulas paratireóides anômalas. No presente artigo, relatamos um caso em que foi observado resultado discordante pelos dois métodos.


Subject(s)
Aged , Female , Humans , Organophosphorus Compounds , Organotechnetium Compounds , Parathyroid Glands , Radiopharmaceuticals , Sensitivity and Specificity
2.
Arq. bras. endocrinol. metab ; 51(6): 1023-1026, ago. 2007. ilus
Article in Portuguese | LILACS | ID: lil-464298

ABSTRACT

A cintilografia das paratireóides tem sido utilizada para detectar glândulas patológicas em pacientes com hiperparatireoidismo, tanto antes quanto após a cirurgia de paratireoidectomia. Apesar da elevada especificidade, a cintilografia das paratireóides pode apresentar resultados falso-positivos. Neste artigo, relatamos o caso de uma paciente transplantada renal, com múltiplas lesões osteolíticas na bacia, interpretadas como tumores marrons, que à cintilografia das paratireóides com sestamibi-99mTc apresentou hipercaptação focal do radiofármaco em topografia de porção anterior do mediastino superior. Esta área hipercaptante foi inicialmente interpretada como glândula paratireóide ectópica, porém, após realização de outros exames de imagem e análise mais detalhada, mostrou-se corresponder a tumor marrom em esterno.


Parathyroid scintigraphies have been used to detect pathological parathyroid glands either before as well as after the parathyroid resection surgery in patients with hyperparathyroidism. Although this test presents high specificity for detection of increased parathyroid glands, there exist causes of false positive results. In the present article, we report a case of a renal transplanted patient, with multiple lytic lesions on pelvic bones reported as brown tumors, who presented a focal uptake in the anterior portion of the superior mediastinum on Tc-99m sestamibi scintigraphy. This focal uptake, initially thought to be an ectopic parathyroid gland, after a more detailed analysis and the performance of other imaging diagnostic tests was demonstrated to be a brown tumor of the sternum.


Subject(s)
Adult , Female , Humans , Bone Neoplasms , Parathyroid Glands , Radiopharmaceuticals , Sternum , Diagnosis, Differential , False Positive Reactions , Hyperparathyroidism , Osteitis Fibrosa Cystica , Tomography, Emission-Computed, Single-Photon
3.
Rev. Assoc. Med. Bras. (1992) ; 53(3): 257-260, maio-jun. 2007. ilus
Article in Portuguese | LILACS | ID: lil-460393

ABSTRACT

OBJETIVOS: Avaliar a utilidade da realização rotineira da imagem tardia de campos pulmonares cinco horas após a ingestão do radiofármaco, no exame de cintilografia para pesquisa de refluxo gastroesofágico (PRGE), com a finalidade de detectar a presença de aspiração pulmonar. MÉTODOS: Foram analisados retrospectivamente 755 exames (400 homens, 355 mulheres) com idade média de 5,18 anos (variando de 1 mês até 94,5 anos). Os exames foram analisados segundo a presença de refluxo, sua freqüência, sua intensidade e a altura do esôfago atingida. Avaliou-se também a presença de atividade radioativa em campos pulmonares nas imagens tardias. RESULTADOS: Trezentos e sete exames apresentaram episódios de refluxo gastroesofágico: 84 exames apresentaram um episódio, 51 apresentaram dois, 45 apresentaram três, 37 apresentaram quatro, 18 apresentaram cinco e 72 apresentaram mais do que cinco episódios. Em 179 exames observou-se refluxo de grau discreto, 69 de grau moderado, 37 de grau acentuado e em 22 exames o grau de refluxo não foi registrado. Quarenta e seis exames apresentaram refluxo até o terço inferior do esôfago, 83 até o terço médio, 161 até o terço superior, 11 até a boca e seis exames não tiveram a altura do refluxo registrada. A imagem tardia foi realizada em 753 exames não se observando nenhum episódio de aspiração pulmonar. CONCLUSÃO: A imagem tardia de campos pulmonares na PRGE nunca foi positiva neste grupo de exames, o que pode ser decorrente da raridade de aspiração pulmonar na nossa amostra de pacientes, da baixa sensibilidade do método para detectar aspiração pulmonar ou de ambos os fatores.


OBJECTIVE: To evaluate the benefit of routine pulmonary imaging with a five hour delay in gastroesophageal reflux scintigraphy (GERS) to detect pulmonary aspiration. METHODS: 755 cases were analyzed (400 men, 355 women) within a wide range of age (1 month up to 94 years, mean of 5.2 years). Presence of reflux, its frequency, severity, and esophageal extension were investigated. Delayed pulmonary images assessed the presence of radioactivity in the lungs. RESULTS: 307 cases of gastroesophageal reflux were identified, 84 of which with just one episode, 51 with 2 episodes, 45 with 3, 37 with 4, 18 with 5, and 72 with more than 5. Concerning severity of these 307 cases 22 had no evaluation, 179 were mild, 69 intermediate, and 37 severe. Degree of esophageal extension was not recorded for 6 cases; in 46 cases reflux covered the lower third of the esophagus, in 83 cases it reached the central third, in 161 the upper third, and in 11 cases it extended to the mouth. Delayed pulmonary images were available in 753 cases and none showed signs of lung aspiration. CONCLUSIONS: Delayed pulmonary images were negative in all cases regardless of the patients' age or severity of the disease. This is suggestive that either lung aspiration is rare in GERS procedures or delayed pulmonary imaging has a sensitivity that is too low to permit detection.


Subject(s)
Adolescent , Adult , Aged , Aged, 80 and over , Child , Child, Preschool , Female , Humans , Infant , Male , Middle Aged , Gastroesophageal Reflux , Radiopharmaceuticals , Respiratory Aspiration , Gastroesophageal Reflux/complications , Hydrogen-Ion Concentration , Lung Diseases , Retrospective Studies , Radiopharmaceuticals/administration & dosage , Respiratory Aspiration/etiology , Sensitivity and Specificity , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL